Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the js_composer domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/tauto/public_html/wp-includes/functions.php on line 6170
Temperature Controller REX-C100 Output SSR – Tera Automation
Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/tauto/public_html/wp-content/plugins/roadthemes-helper/less/lessc.inc.php on line 717

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/tauto/public_html/wp-content/plugins/roadthemes-helper/less/lessc.inc.php on line 1768

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/tauto/public_html/wp-content/plugins/roadthemes-helper/less/lessc.inc.php on line 2424

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/tauto/public_html/wp-content/plugins/roadthemes-helper/less/lessc.inc.php on line 2478

Permintaan Faktur Pajak hanya dilayani sampai tanggal 10 bulan berikutnya, lebih dari tanggal itu tidak bisa diproses, Mohon segera mendaftarkan data anda dengan login / register. Waktu Operasional : Senin - Minggu pukul 08.00 - 17.00 WIB.

Temperature Controller REX-C100 Output SSR

Original price was: Rp100,000.00.Current price is: Rp90,000.00.

SKU: ed8f5668d1b3 Category:
Share this product

Description

  • Measuring accuracy: 0.5%FS
  • Cold-end compensation tolerance: ~2C(can be modified by software in 0~50C)
  • Resolution: 14 bit
  • Sampling cycle: 0.5 Sec
  • power supply: AC100 to 240V
  • output : Relay
  • Process value (PV), Setting value (SV)
  • Output, alarm and self-tuning can be indicated by: LED
  • PIN control (including ON/OFF, step-type PID and continuous PID)
  • Self-tuning control
  • Relay output: contact capacity 250V AC 3A (resistive load)
  • Alarm function output: 1 way
  • Contact capacity of output: 250V AC 3A (resistive load)
  • Setting value (SV): identical to measuring range (PV)
  • Proportional band (P): 0 ~ full range (ON/OFF control when set to 0)
  • Integral time (I) and Derivative time (D) : 0 ~ 3600 sec (No integral action when set to 0)
  • Heat-reset proportional cycle: 1 ~ 100 sec
  • Detective temperature range 0 to 400°C
  • Power Consumption: 10 VA

 